14.04.2014
Quality control of inert gas applications
New gas analyser "PA 7.0"
To help simplify the work of staff with quality responsibilities in companies with gas plants, WITT has updated its range of analysers: with the PA 7.0 there is now a completely redesigned instrument on the market for measuring the concentration of oxygen and carbon dioxide.
The new PA 7.0 has many applications for use in the food industry, for weld shielding gas analysis or in any process requiring critical limits of Oxygen and CO2. One of the unique features of the new analyser is that it can do two jobs at the same time. In addition to continuous in-line gas mix monitoring, a random sample can be taken with a sampling needle, such as for checking foodstuffs packages in a protected atmosphere. This double functionality makes the PA 7.0 the benchmark instrument in its class.
A further advantage is its very low measuring gas requirement. In practice, depending on the application, WITT states that as little as about 3 ml of gas is sufficient for a reliable analysis. The measuring cells (chemical, zirconium and infrared) work from 0-100 percent.
Featuring all the capabilities of the series 6 predecessor the improved PA 7.0 includes a redesigned hygienic stainless steel housing is ideally suited to meet the demands of industrial applications. The USB connection and the SD card slot for data transmission and updates are easily accessible on the front. For communication with other instruments and optimum integration in existing systems, sufficient connections are available (digital inputs and outputs, 24 V inputs and outputs, relays).
The PA 7.0 also has further features which make it an indispensable quality assurance instrument: if an individually-set limit value is reached, the PA will raise the alarm or trip a voltfree contact, for example to interrupt a supply of gas.
By means of modern electronics and pressure transmitters, the flow is continuously monitored, and the pump capacity is varied to meet the required demand, the PA 7.0 even detects a needle blockage and signals an alarm.
Measurement results can be assigned according to user and product. A data memory stores the 500 most recent measurements. Using data export and the purpose-designed OBCC software, the user can document all measurement results in digital form and analyse them.
The gas analyser needs little maintenance and can be calibrated with a simple two-point procedure.
With its small dimensions and light weight, space can be found for the compact upright appliance in all places where work is carried out with gas mixtures. An optional carrying handle makes its mobile use easy and also doubles as a stand for ideal positioning.